News
科思
/
/
/
Outcomes with bioabsorbable vascular scaffolds versus everolimus-eluting stents Insights from randomized trials

Outcomes with bioabsorbable vascular scaffolds versus everolimus-eluting stents Insights from randomized trials

  • Categories:Academic Paper
  • Author:
  • Origin:
  • Time of issue:2015-08-04 08:54
  • Views:

(Summary description)Bioresorbable vascular scaffolds (BVS) have been shown to be non-inferior to second generation drug eluting stents in recent clinical trials. However, the trials were not powered for individual endpoints and there is concern for increased device thrombosis with BVS.

Outcomes with bioabsorbable vascular scaffolds versus everolimus-eluting stents Insights from randomized trials

(Summary description)Bioresorbable vascular scaffolds (BVS) have been shown to be non-inferior to second generation drug eluting stents in recent clinical trials. However, the trials were not powered for individual endpoints and there is concern for increased device thrombosis with BVS.

  • Categories:Academic Paper
  • Author:
  • Origin:
  • Time of issue:2015-08-04 08:54
  • Views:
Information

  BACKGROUND: Bioresorbable vascular scaffolds (BVS) have been shown to be non-inferior to second generation drug eluting stents in recent clinical trials. However, the trials were not powered for individual endpoints and there is concern for increased device thrombosis with BVS.

  METHODS: We performed a systematic search for randomized clinical trials of BVS versus EES. Efficacy outcomes were target lesion revascularization (TLR) and target vessel revascularization (TVR). Safety outcomes were death, myocardial infarction (MI), and device thrombosis. Meta-regression analyses were performed to evaluate the association of device thrombosis with clinical characteristics (percent patients with acute coronary syndrome) and device deployment characteristics (percent with post stent balloon dilation).

  RESULTS: We identified six RCTs that enrolled 3738 patients. When compared with EES, BVS was associated with similar risk of TLR (RR=1.06; 95% CI 0.73-1.54), TVR (RR=1.00; 95% CI 0.74-1.35), death (RR=1.11; 95% CI 0.53-2.33) and cardiovascular death (RR=1.39; 95% CI 0.43-4.43) but numerically higher MI (RR=1.35; 95% CI 0.98-1.86) and definite or probable device thrombosis (RR=2.11; 95% CI 0.99-4.47). In a sensitivity analysis using the Peto odds ratio method, the risk of definite or probable device thrombosis was significantly increased (OR=2.08; 95% CI 1.06-4.08; P=0.03), although this did not reach statistical significance in four other models. The risk of definite or probable device thrombosis with BVS was reduced in trials where more post stent balloon dilation was used and in patients without acute coronary syndrome. Moreover, trial sequential analysis showed that the cumulative z-curve crossed the conventional boundary and not the trial sequential boundary, indicating lack of robust data to support increased definite or probable device thrombosis with BVS.

  CONCLUSIONS: In patients with noncomplex obstructive coronary disease, BVS are comparable to EES for most efficacy and safety outcomesexcept for a numerical increase in device thrombosis and MI. The risk of the latter outcomes was mitigated in trials where more post stent balloon dilation was used and in patients without acute coronary syndrome. Moreover, with only 3738 patients, the trials are underpowered to detect a difference in rare events such as device thrombosis.

PeriSorb® fully degradable peripheral vascular stent completes the first FIM trial enrollment
2021 12-25

PeriSorb® fully degradable peripheral vascular stent completes the first FIM trial enrollment

This is the world's first 3D printed fully degradable peripheral stent implanted in the human body, marking that my country's 3D printing fully degradable peripheral stent with completely independent intellectual property rights has taken the lead in entering the clinical trial stage, and it also marks that my country's 3D printing technology has advanced to the world's leading level. A big step.
Beijing adds 1,150 municipal-level "specialized, special and new" small and medium-sized enterprises
2021 12-03

Beijing adds 1,150 municipal-level "specialized, special and new" small and medium-sized enterprises

On December 1, the Beijing Economic and Information Bureau announced the list of the second to seventh batch of "specialized, special and new" small and medium-sized enterprises in Beijing in 2021. The list includes 1,150 small and medium-sized enterprises including Labtech, Digital Video, Geling Shentong, Moji Fengyun Technology, etc.
Beijing Amet was recognized as a "specialized, special and new" enterprise
2021 12-02

Beijing Amet was recognized as a "specialized, special and new" enterprise

On December 1, 2021, the Beijing Municipal Bureau of Economy and Information issued an announcement on the seventh batch of "specialized, refined, and new" small and medium-sized enterprises in 2021. The announcement announced that Beijing Amet Medical Equipment Co., Ltd. was recognized as a "specialized, refined and new" enterprise. This event marks that Amet, as an innovative enterprise, has reached a high level in terms of scientific research strength, technical level and influence, and has been recognized by the competent government departments.

Company Information

Beijing Advanced Medical Technologies,Ltd.Inc.

Contact Us

Address: Building 11, Zhongguancun Medical Equipment Park, No. 26, Yongwang West Road, Daxing District, Beijing

Tel:010-6297-7955           E-Mail:amt@ametcorp.com